Err44 on a Monarch NICE3000new integrated controller means the down-limit signal was active while running downward. It is a fault we handle regularly on NICE3000new systems overseas, and in most cases it comes from sub-code 101 rather than a failed main board.
Possible Causes
- Sub-code 101: down-limit signal active while the elevator runs downward
Step-by-Step Troubleshooting
- 1. Sub-code 101: a. check down-limit signal type (NO/NC) b. check the down-limit switch contact c. a switch mounted too high will also trigger at normal terminal approach
Pro Tip From the Field
Check the down-limit switch contact and NO/NC setting; a switch mounted too high will also trip at normal terminal approach.
Still stuck on this fault? Our engineers repair and supply Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board and part we ship is 100% run-tested before dispatch, with a 12-month warranty.