Monarch NICE3000new Err41 — Safety Circuit Open: Causes and Fixes

Err41 means the safety circuit signal is open on the NICE3000new — the controller sees the safety chain broken and refuses to run. This is a safety-critical fault: never bypass it permanently.

First: Check Your Detection-Point Settings

If the safety/door-lock circuit uses low-voltage detection points: set F5-04=4, F5-05=5, F5-37=F5-38=F5-39=0. For high-voltage detection points: set F5-04=F5-05=0, F5-37=4, F5-38=F5-39=5. Wrong settings here cause false Err41.

Troubleshooting (Sub-code 101)

  • Check each safety circuit switch and its state — machine room, pit, car top and safety gear switches one by one.
  • Check the external supply to the safety circuit.
  • Check the safety circuit contactor operation.
  • Verify the feedback contact type (NO/NC) matches the parameter setting.

Pro Tip From the Field

On elevators that sat idle for weeks, pit switches and car-top stop switches are the first suspects — moisture and dust corrode the contacts.


Still stuck on this fault? Our engineers repair Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board we sell is 100% run-tested with a 12-month warranty, MOQ 1 piece, and free remote parameter-setup support until your elevator runs.

Browse all codes in our free NICE3000 fault code library.


评论

发表回复

您的邮箱地址不会被公开。 必填项已用 * 标注