Err41 means the safety circuit signal is open on the NICE3000new — the controller sees the safety chain broken and refuses to run. This is a safety-critical fault: never bypass it permanently.
First: Check Your Detection-Point Settings
If the safety/door-lock circuit uses low-voltage detection points: set F5-04=4, F5-05=5, F5-37=F5-38=F5-39=0. For high-voltage detection points: set F5-04=F5-05=0, F5-37=4, F5-38=F5-39=5. Wrong settings here cause false Err41.
Troubleshooting (Sub-code 101)
- Check each safety circuit switch and its state — machine room, pit, car top and safety gear switches one by one.
- Check the external supply to the safety circuit.
- Check the safety circuit contactor operation.
- Verify the feedback contact type (NO/NC) matches the parameter setting.
Pro Tip From the Field
On elevators that sat idle for weeks, pit switches and car-top stop switches are the first suspects — moisture and dust corrode the contacts.
Still stuck on this fault? Our engineers repair Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board we sell is 100% run-tested with a 12-month warranty, MOQ 1 piece, and free remote parameter-setup support until your elevator runs.