Monarch NICE3000new Err37 — Brake Contactor Feedback Abnormal: Causes and Fixes

Err37 on a Monarch NICE3000new integrated controller means the brake contactor feedback disagrees with output/travel feedback. It is a fault we handle regularly on NICE3000new systems overseas, and in most cases it comes from sub-code 101 rather than a failed main board.

Possible Causes

  • Sub-code 101: brake contactor output vs brake feedback mismatch; 102: duplicated feedback contacts disagree; 103: brake contactor output vs brake travel 1 feedback mismatch; 104: duplicated travel 1 feedback disagree; 105: brake contactor feedback active before start; 106: output vs brake travel 2 feedback mismatch; 107: duplicated travel 2 feedback disagree; 108: output vs travel 1 feedback on I/O expansion board mismatch; 109: output vs travel 2 feedback on I/O expansion board mismatch

Step-by-Step Troubleshooting

  1. 1. Sub-code 101: a. check the brake contactor pulls in b. check feedback NO/NC setting c. check feedback wiring
  2. 2. Sub-code 102: a. check duplicated feedback contact NO/NC settings b. verify all duplicated feedback states agree
  3. 3. Sub-codes 103, 105: check brake travel 1/2 feedback NO/NC settings and wiring
  4. 4. Sub-codes 108, 109: a. check travel 1/2 feedback NO/NC settings on the expansion board b. check travel feedback wiring
  5. 5. Sub-codes 104, 107: a. check duplicated travel 1/2 feedback NO/NC settings b. verify duplicated feedback states agree
  6. 6. Sub-code 105: check for false triggering of the brake contactor feedback

Pro Tip From the Field

Err37 has many sub-codes – start with the brake contactor pull-in and its NO/NC feedback wiring.


Still stuck on this fault? Our engineers repair and supply Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board and part we ship is 100% run-tested before dispatch, with a 12-month warranty.