Err24 on a Monarch NICE3000new integrated controller means the control-board real-time clock data is abnormal. It is a fault we handle regularly on NICE3000new systems overseas, and in most cases it comes from sub-code 101 rather than a failed main board.
Possible Causes
- Sub-code 101: control board clock data abnormal
Step-by-Step Troubleshooting
- 1. a. Replace the clock battery b. Replace the main control board
Pro Tip From the Field
Err24 is usually a dead clock battery – replace the battery, and if it returns, replace the main control board.
Still stuck on this fault? Our engineers repair and supply Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board and part we ship is 100% run-tested before dispatch, with a 12-month warranty.