Err17 on a Monarch NICE3000new integrated controller means encoder signal noise appeared while motor tuning was running. It is a fault we handle regularly on NICE3000new systems overseas, and in most cases it comes from sub-code 1 rather than a failed main board.
Possible Causes
- Sub-code 1: reserved; Sub-code 2: sine-cosine encoder signal abnormal; Sub-code 3: UVW encoder signal abnormal
Step-by-Step Troubleshooting
- 1. This fault occurs only during motor tuning.
- 2. Sub-code 2: a. heavy interference on sine-cosine C/D/Z signals — separate encoder wiring from power cables, check system grounding b. check PG-card wiring
- 3. Sub-code 3: a. heavy interference on UVW signals — same treatment b. check PG-card wiring
Pro Tip From the Field
Err17 only occurs during tuning – separate encoder wiring from power cables and check the PG card before re-tuning.
Still stuck on this fault? Our engineers repair and supply Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board and part we ship is 100% run-tested before dispatch, with a 12-month warranty.