Err45 on a Monarch NICE3000new integrated controller means a forced-deceleration switch distance or signal was abnormal. It is a fault we handle regularly on NICE3000new systems overseas, and in most cases it comes from sub-code 101 rather than a failed main board.
Possible Causes
- Sub-code 101: insufficient down forced-deceleration distance at learning start; 102: insufficient up forced-deceleration distance at learning start; 103: abnormal forced-deceleration distance in normal run; 106: abnormal level-2 up/down forced-deceleration signal during learning; 107: abnormal level-3 up/down forced-deceleration signal during learning
Step-by-Step Troubleshooting
- 1. Sub-codes 101–103: a. check up/down forced-deceleration switch contacts b. verify signal type (NO/NC) c. verify mounting distance meets the deceleration requirement for this speed. Sub-code 106: a. check level-2 up/down switches are not swapped b. verify signal type (NO/NC). Sub-code 107: a. check level-3 up/down switches are not swapped b. verify signal type (NO/NC)
Pro Tip From the Field
Check the up/down forced-deceleration switch contacts, NO/NC setting and mounting distance for the rated speed.
Still stuck on this fault? Our engineers repair and supply Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board and part we ship is 100% run-tested before dispatch, with a 12-month warranty.

发表回复