Err43 on a Monarch NICE3000new integrated controller means the up-limit signal was active while running upward. It is a fault we handle regularly on NICE3000new systems overseas, and in most cases it comes from sub-code 101 rather than a failed main board.
Possible Causes
- Sub-code 101: up-limit signal active while the elevator runs upward
Step-by-Step Troubleshooting
- 1. Sub-code 101: a. check up-limit signal type (NO/NC) b. check the up-limit switch contact c. a switch mounted too low will also trigger at normal terminal approach
Pro Tip From the Field
Check the up-limit switch contact and its NO/NC setting; a switch mounted too low will also trip at normal terminal approach.
Still stuck on this fault? Our engineers repair and supply Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board and part we ship is 100% run-tested before dispatch, with a 12-month warranty.