Monarch NICE3000new Err33 — Elevator Speed Abnormal: Causes and Fixes

Err33 on a Monarch NICE3000new integrated controller means the measured speed exceeded the safe limit. It is a fault we handle regularly on NICE3000new systems overseas, and in most cases it comes from sub-code 101 rather than a failed main board.

Possible Causes

  • Sub-code 101: overspeed in high-speed run; 102: overspeed in inspection or well-learning run; 103: overspeed during coasting; 104, 105: overspeed during emergency run; 106: excessive board speed-measurement deviation

Step-by-Step Troubleshooting

  1. 1. Sub-code 101: a. verify encoder settings and wiring b. verify motor nameplate parameters and re-tune
  2. 2. Sub-code 102: lower inspection speed or re-tune the motor
  3. 3. Sub-code 103: a. verify the star-sealing function works b. verify motor U/V/W phase sequence
  4. 4. Sub-codes 104, 105: a. match the emergency power capacity b. verify emergency run speed settings
  5. 5. Sub-code 106: a. check encoder wiring b. check SPI communication quality between control boards

Pro Tip From the Field

For Err33, verify encoder settings and motor nameplate parameters and re-tune; check emergency-power capacity for sub-codes 104/105.


Still stuck on this fault? Our engineers repair and supply Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board and part we ship is 100% run-tested before dispatch, with a 12-month warranty.