Err29 on a Monarch NICE3000new integrated controller means the star-sealing (bridging) contactor feedback disagrees with output. It is a fault we handle regularly on NICE3000new systems overseas, and in most cases it comes from sub-code 101, 102 rather than a failed main board.
Possible Causes
- Sub-code 101, 102: PM star-sealing contactor feedback abnormal
Step-by-Step Troubleshooting
- 1. Sub-code 101: check the sealing-contactor feedback on the main board
- 2. Sub-code 102: check feedback on the I/O expansion board
- 3. Verify input signal type (NO/NC)
- 4. Check the contactor and its feedback contacts operate correctly
- 5. Check the sealing-contactor coil supply
Pro Tip From the Field
Check the sealing-contactor feedback point and its NO/NC setting on the main board or I/O expansion board.
Still stuck on this fault? Our engineers repair and supply Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board and part we ship is 100% run-tested before dispatch, with a 12-month warranty.