Err16 on the NICE3000new means the drive cannot keep current (or speed) under control. The sub-code on the keypad tells you which loop failed:
What the Sub-Codes Mean
- Sub-code 1, 2: excessive current deviation
- Sub-code 3: excessive (low) speed deviation
Troubleshooting
- Sub-codes 1–2: check the input voltage is not low (common on temporary construction supplies); check wiring between controller and motor; check the run contactor operation.
- Sub-code 3: check the encoder loop — verify pulses per revolution, check for interference, route encoder wiring in a separate conduit with single-point shield grounding, and verify mounting and shaft coupling. Then verify motor parameters and re-tune. Finally, try increasing torque limit F2-08.
Still stuck on this fault? Our engineers repair Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board we sell is 100% run-tested with a 12-month warranty, MOQ 1 piece, and free remote parameter-setup support until your elevator runs.
Browse all codes in our free NICE3000 fault code library.