Err10 means the NICE3000new controller has run above rated current for an extended period. The controller is protecting itself — something is forcing it to work too hard.
Typical Causes
- Excessive mechanical resistance (brake not fully opening, tight guide shoes)
- Poor balance coefficient
- Abnormal encoder feedback
- Inaccurate motor tuning causing high current
- Motor phase sequence reversed
Step-by-Step Troubleshooting
- 1. Mechanical: check the brake opens fully and the brake supply is normal; check the balance coefficient; check for over-tight guide shoes.
- 2. Motor and tuning: verify encoder feedback and settings (for PM motors verify the initial angle); verify motor parameters and re-tune; verify motor U/V/W phase sequence.
- 3. For rope-slip tests, use the dedicated F3-24 rope-slip function instead of forcing a run.
Pro Tip From the Field
Before touching any parameters, put the machine in inspection and watch the current reading during a short run. If current is high the moment the brake opens, look at the brake — not the electronics.
Still stuck on this fault? Our engineers repair Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board we sell is 100% run-tested with a 12-month warranty, MOQ 1 piece, and free remote parameter-setup support until your elevator runs.