Monarch NICE3000new Err09 — Undervoltage Fault: Causes and Fixes

Err09 means the NICE3000new controller detected input voltage below the protection threshold. It is usually a power-supply problem, not a board failure — but a faulty drive board can also trigger it.

Possible Causes

  • Momentary input power loss
  • Input voltage too low
  • Drive/control board fault

Step-by-Step Troubleshooting

  • 1. Measure whether the external supply is low or unstable.
  • 2. Check whether power is interrupted during the run.
  • 3. Check that all supply terminal connections are tight — a loose terminal can cause intermittent undervoltage.
  • 4. If the supply is normal, contact your distributor or the manufacturer — the drive board may be faulty.

Pro Tip From the Field

In areas with unstable grids, Err09 often appears during elevator start-up when the inrush current pulls the bus down. Check the supply cable size and terminal tightness first.


Still stuck on this fault? Our engineers repair Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board we sell is 100% run-tested with a 12-month warranty, MOQ 1 piece, and free remote parameter-setup support until your elevator runs.